Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
JMIR Res Protoc ; 13: e57329, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38669065

RESUMO

BACKGROUND: Relative motion between the residual limb and socket in individuals with transtibial limb loss can lead to substantial consequences that limit mobility. Although assessments of the relative motion between the residual limb and socket have been performed, there remains a substantial gap in understanding the complex mechanics of the residual limb-socket interface during dynamic activities that limits the ability to improve socket design. However, dynamic stereo x-ray (DSX) is an advanced imaging technology that can quantify 3D bone movement and skin deformation inside a socket during dynamic activities. OBJECTIVE: This study aims to develop analytical tools using DSX to quantify the dynamic, in vivo kinematics between the residual limb and socket and the mechanism of residual tissue deformation. METHODS: A lower limb cadaver study will first be performed to optimize the placement of an array of radiopaque beads and markers on the socket, liner, and skin to simultaneously assess dynamic tibial movement and residual tissue and liner deformation. Five cadaver limbs will be used in an iterative process to develop an optimal marker setup. Stance phase gait will be simulated during each session to induce bone movement and skin and liner deformation. The number, shape, size, and placement of each marker will be evaluated after each session to refine the marker set. Once an optimal marker setup is identified, 21 participants with transtibial limb loss will be fitted with a socket capable of being suspended via both elevated vacuum and traditional suction. Participants will undergo a 4-week acclimation period and then be tested in the DSX system to track tibial, skin, and liner motion under both suspension techniques during 3 activities: treadmill walking at a self-selected speed, at a walking speed 10% faster, and during a step-down movement. The performance of the 2 suspension techniques will be evaluated by quantifying the 3D bone movement of the residual tibia with respect to the socket and quantifying liner and skin deformation at the socket-residuum interface. RESULTS: This study was funded in October 2021. Cadaver testing began in January 2023. Enrollment began in February 2024. Data collection is expected to conclude in December 2025. The initial dissemination of results is expected in November 2026. CONCLUSIONS: The successful completion of this study will help develop analytical methods for the accurate assessment of residual limb-socket motion. The results will significantly advance the understanding of the complex biomechanical interactions between the residual limb and the socket, which can aid in evidence-based clinical practice and socket prescription guidelines. This critical foundational information can aid in the development of future socket technology that has the potential to reduce secondary comorbidities that result from complications of poor prosthesis load transmission. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): DERR1-10.2196/57329.


Assuntos
Extremidade Inferior , Pele , Tíbia , Humanos , Cotos de Amputação/diagnóstico por imagem , Cotos de Amputação/fisiopatologia , Membros Artificiais , Fenômenos Biomecânicos/fisiologia , Cadáver , Extremidade Inferior/diagnóstico por imagem , Extremidade Inferior/cirurgia , Extremidade Inferior/fisiologia , Movimento/fisiologia , Pele/diagnóstico por imagem , Tíbia/diagnóstico por imagem , Tíbia/cirurgia
2.
Front Bioeng Biotechnol ; 9: 697651, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34447740

RESUMO

Individuals with transfemoral amputation experience relative motion between their residual limb and prosthetic socket, which can cause inefficient dynamic load transmission and secondary comorbidities that limit mobility. Accurately measuring the relative position and orientation of the residual limb relative to the prosthetic socket during dynamic activities can provide great insight into the complex mechanics of the socket/limb interface. Five participants with transfemoral amputation were recruited for this study. All participants had a well-fitting, ischial containment socket and were also fit with a compression/release stabilization socket. Participants underwent an 8-wk, randomized crossover trial to compare differences between socket types. Dynamic stereo x-ray was used to quantify three-dimensional residual bone kinematics relative to the prosthetic socket during treadmill walking at self-selected speed. Comfort, satisfaction, and utility were also assessed. There were no significant differences in relative femur kinematics between socket types in the three rotational degrees of freedom, as well as anterior-posterior and medial-lateral translation (p > 0.05). The ischial containment socket demonstrated significantly less proximal-distal translation (pistoning) of the femur compared to the compression/release stabilization socket during the gait cycle (p < 0.05), suggesting that the compression/release stabilization socket provided less control of the residual femur during distal translation. No significant differences in comfort and utility were found between socket types (p > 0.05). The quantitative, dynamic analytical tools used in the study were sensitive to distinguish differences in three-dimensional residual femur motion between two socket types, which can serve as a platform for future comparative effectiveness studies of socket technology.

3.
Proc Biol Sci ; 288(1943): 20202095, 2021 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-33468002

RESUMO

The arch of the human foot is unique among hominins as it is compliant at ground contact but sufficiently stiff to enable push-off. These behaviours are partly facilitated by the ligamentous plantar fascia whose role is central to two mechanisms. The ideal windlass mechanism assumes that the plantar fascia has a nearly constant length to directly couple toe dorsiflexion with a change in arch shape. However, the plantar fascia also stretches and then shortens throughout gait as the arch-spring stores and releases elastic energy. We aimed to understand how the extensible plantar fascia could behave as an ideal windlass when it has been shown to strain throughout gait, potentially compromising the one-to-one coupling between toe arc length and arch length. We measured foot bone motion and plantar fascia elongation using high-speed X-ray during running. We discovered that toe plantarflexion delays plantar fascia stretching at foot strike, which probably modifies the distribution of the load through other arch tissues. Through a pure windlass effect in propulsion, a quasi-isometric plantar fascia's shortening is delayed to later in stance. The plantar fascia then shortens concurrently to the windlass mechanism, likely enhancing arch recoil at push-off.


Assuntos
Fáscia , Corrida , Fenômenos Biomecânicos , , Marcha , Humanos
4.
Artigo em Inglês | MEDLINE | ID: mdl-32211386

RESUMO

The intricate motion of the small bones of the feet are critical for its diverse function. Accurately measuring the 3-dimensional (3D) motion of these bones has attracted much attention over the years and until recently, was limited to invasive techniques or quantification of functional segments using multi-segment foot models. Biplanar videoradiography and model-based scientific rotoscoping offers an exciting alternative that allows us to focus on the intricate motion of individual bones in the foot. However, scientific rotoscoping, the process of rotating and translating a 3D bone model so that it aligns with the captured x-ray images, is either semi- or completely manual and it is unknown how much human error affects tracking results. Thus, the aim of this study was to quantify the inter- and intra-operator reliability of manually rotoscoping in vivo bone motion of the tibia, talus, and calcaneus during running. Three-dimensional CT bone volumes and high-speed biplanar videoradiography images of the foot were acquired on six participants. The six-degree-of-freedom motions of the tibia, talus, and calcaneus were determined using a manual markerless registration algorithm. Two operators performed the tracking, and additionally, the first operator re-tracked all bones, to test for intra-operator effects. Mean RMS errors were 1.86 mm and 1.90° for intra-operator comparisons and 2.30 mm and 2.60° for inter-operator comparisons across all bones and planes. The moderate to strong similarity values indicate that tracking bones and joint kinematics between sessions and operators is reliable for running. These errors are likely acceptable for defining gross joint angles. However, this magnitude of error may limit the capacity to perform advanced analyses of joint interactions, particularly those that require precise (sub-millimeter) estimates of bone position and orientation. Optimizing the view and image quality of the biplanar videoradiography system as well as the automated tracking algorithms for rotoscoping bones in the foot are required to reduce these errors and the time burden associated with the manual processing.

5.
Artigo em Inglês | MEDLINE | ID: mdl-31508415

RESUMO

Measuring motion of the human foot presents a unique challenge due to the large number of closely packed bones with congruent articulating surfaces. Optical motion capture (OMC) and multi-segment models can be used to infer foot motion, but might be affected by soft tissue artifact (STA). Biplanar videoradiography (BVR) is a relatively new tool that allows direct, non-invasive measurement of bone motion using high-speed, dynamic x-ray images to track individual bones. It is unknown whether OMC and BVR can be used interchangeably to analyse multi-segment foot motion. Therefore, the aim of this study was to determine the agreement in kinematic measures of dynamic activities. Nine healthy participants performed three walking and three running trials while BVR was recorded with synchronous OMC. Bone position and orientation was determined through manual scientific-rotoscoping. The OMC and BVR kinematics were co-registered to the same coordinate system, and BVR tracking was used to create virtual markers for comparison to OMC during dynamic trials. Root mean square (RMS) differences in marker positions and joint angles as well as a linear fit method (LFM) was used to compare the outputs of both methods. When comparing BVR and OMC, sagittal plane angles were in good agreement (ankle: R2 = 0.947, 0.939; Medial Longitudinal Arch (MLA) Angle: R2 = 0.713, 0.703, walking and running, respectively). When examining the ankle, there was a moderate agreement between the systems in the frontal plane (R2 = 0.322, 0.452, walking and running, respectively), with a weak to moderate correlation for the transverse plane (R2 = 0.178, 0.326, walking and running, respectively). However, root mean squared error (RMSE) showed angular errors ranging from 1.06 to 8.31° across the planes (frontal: 3.57°, 3.67°, transverse: 4.28°, 4.70°, sagittal: 2.45°, 2.67°, walking and running, respectively). Root mean square (RMS) differences between OMC and BVR marker trajectories were task dependent with the largest differences in the shank (6.0 ± 2.01 mm) for running, and metatarsals (3.97 ± 0.81 mm) for walking. Based on the results, we suggest BVR and OMC provide comparable solutions to foot motion in the sagittal plane, however, interpretations of out-of-plane movement should be made carefully.

6.
Hum Mov Sci ; 36: 20-34, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24911782

RESUMO

Fractal patterns characterize healthy biological systems and are considered to reflect the ability of the system to adapt to varying environmental conditions. Previous research has shown that fractal patterns in gait are altered following natural aging or disease, and this has potential negative consequences for gait adaptability that can lead to increased risk of injury. However, the flexibility of a healthy neurological system to exhibit different fractal patterns in gait has yet to be explored, and this is a necessary step toward understanding human locomotor control. Fifteen participants walked for 15min on a treadmill, either in the absence of a visual stimulus or while they attempted to couple the timing of their gait with a visual metronome that exhibited a persistent fractal pattern (contained long-range correlations) or a random pattern (contained no long-range correlations). The stride-to-stride intervals of the participants were recorded via analog foot pressure switches and submitted to detrended fluctuation analysis (DFA) to determine if the fractal patterns during the visual metronome conditions differed from the baseline (no metronome) condition. DFA α in the baseline condition was 0.77±0.09. The fractal patterns in the stride-to-stride intervals were significantly altered when walking to the fractal metronome (DFA α=0.87±0.06) and to the random metronome (DFA α=0.61±0.10) (both p<.05 when compared to the baseline condition), indicating that a global change in gait dynamics was observed. A variety of strategies were identified at the local level with a cross-correlation analysis, indicating that local behavior did not account for the consistent global changes. Collectively, the results show that a gait dynamics can be shifted in a prescribed manner using a visual stimulus and the shift appears to be a global phenomenon.


Assuntos
Fractais , Marcha/fisiologia , Adulto , Envelhecimento , Fenômenos Biomecânicos , Teste de Esforço , Feminino , Humanos , Masculino , Fatores de Tempo , Percepção Visual , Caminhada , Adulto Jovem
7.
Gait Posture ; 36(3): 537-40, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22739049

RESUMO

The purpose of this study was to determine whether providing subsensory stochastic-resonance mechanical vibration to the foot soles of elderly walkers could decrease gait variability. In a randomized double-blind controlled trial, 29 subjects engaged in treadmill walking while wearing sandals customized with three actuators capable of producing stochastic-resonance mechanical vibration embedded in each sole. For each subject, we determined a subsensory level of vibration stimulation. After a 5-min acclimation period of walking with the footwear, subjects were asked to walk on the treadmill for six trials, each 30s long. Trials were pair-wise random: in three trials, actuators provided subsensory vibration; in the other trials, they did not. Subjects wore reflective markers to track body motion. Stochastic-resonance mechanical stimulation exhibited baseline-dependent effects on spatial stride-to-stride variability in gait, slightly increasing variability in subjects with least baseline variability and providing greater reductions in variability for subjects with greater baseline variability (p<.001). Thus, applying stochastic-resonance mechanical vibrations on the plantar surface of the foot reduces gait variability for subjects with more variable gait. Stochastic-resonance mechanical vibrations may provide an effective intervention for preventing falls in healthy elderly walkers.


Assuntos
Acidentes por Quedas/prevenção & controle , Marcha/fisiologia , Sapatos , Vibração/uso terapêutico , Idoso , Antropometria , Método Duplo-Cego , Teste de Esforço/métodos , Retroalimentação Fisiológica , Feminino , Avaliação Geriátrica/métodos , Humanos , Masculino , Ruído , Estudos Prospectivos , Valores de Referência , Análise e Desempenho de Tarefas , Caminhada/fisiologia
8.
IEEE Trans Neural Syst Rehabil Eng ; 19(5): 567-77, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21859635

RESUMO

Recent advances in design of powered artificial legs have led to increased potential to allow lower limb amputees to actively recover from stumbles. To achieve this goal, promptly and accurately identifying stumbles is essential. This study aimed to 1) select potential stumble detection data sources that react reliably and quickly to stumbles and can be measured from a prosthesis, and 2) investigate two different approaches based on selected data sources to detect stumbles and classify stumble types in patients with transfemoral (TF) amputations during ambulation. In the experiments, the normal gait of TF amputees was perturbed by a controllable treadmill or when they walked on an obstacle course. The results showed that the acceleration of prosthetic foot can accurately detect the tested stumbling events 140-240 ms before the critical timing of falling and precisely classify the stumble type. However, the detector based on foot acceleration produced high false alarm rates, which challenged its real application. Combining electromyographic (EMG) signals recorded from the residual limb with the foot acceleration significantly reduced the false alarm rate but sacrificed the detection response time. The results of this study may lead to design of a stumble detection system for instrumented, powered artificial legs; however, continued engineering efforts are required to improve the detection performance and resolve the challenges that remain for implementing the stumble detector on prosthetic legs.


Assuntos
Membros Artificiais , Marcha/fisiologia , Aceleração , Acidentes por Quedas/prevenção & controle , Adulto , Algoritmos , Amputação Cirúrgica , Eletromiografia , Processamento Eletrônico de Dados , Feminino , Pé/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Força Muscular/fisiologia , Equilíbrio Postural/fisiologia , Desenho de Prótese , Caminhada/fisiologia
9.
Gait Posture ; 30(3): 383-7, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19632845

RESUMO

The purpose of this study was to investigate the effect of subsensory vibratory noise applied to the soles of the feet on gait variability in a population of elderly recurrent fallers compared to non-fallers and young controls. Eighteen elderly recurrent fallers and 18 elderly non-fallers were recruited from the MOBILIZE Boston Study (MBS), a population-based cohort study investigating novel risk factors for falls. Twelve young participants were included as controls. Participants performed three 6-min walking trials while wearing a pair of insoles containing vibrating actuators. During each trial, the noise stimulus was applied for 3 of the 6min, and differences in stride, stance, and swing time variability were analyzed between noise and no-noise conditions. The use of vibrating insoles significantly reduced stride, stance, and swing time variability measures for elderly recurrent fallers. Elderly non-fallers also demonstrated significant reductions in stride and stance time variability. Although young participants showed decreases in all variability measures, the results did not achieve statistical significance. Gait variability reductions with noise were similar between the elderly recurrent fallers and elderly non-fallers. This study supports the hypothesis that subsensory vibratory noise applied to the soles of the feet can reduce gait variability in elderly participants. Future studies are needed to determine if this intervention reduces falls risk.


Assuntos
Acidentes por Quedas , Pé/fisiopatologia , Marcha/fisiologia , Aparelhos Ortopédicos , Acidentes por Quedas/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Retroalimentação , Feminino , Humanos , Modelos Lineares , Masculino , Equilíbrio Postural/fisiologia , Fatores de Risco , Sapatos , Vibração
10.
Aviat Space Environ Med ; 76(5): 441-7, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15892541

RESUMO

BACKGROUND: Exercise is a promising countermeasure to the physiological deconditioning experienced in microgravity, but has not proven effective in eliminating the ongoing loss of bone mineral, most likely due to the lack of high-impact forces and loading rates during in-flight activity. We wanted to determine lower-extremity response to high-impact jumping exercises in true and simulated microgravity and establish if 1-G force magnitudes can be achieved in a weightless environment. METHODS: Jumping experiments were performed in a ground-based zero-gravity simulator (ZGS) in 1 G, and during parabolic flight with a gravity-replacement system. There were 12 subjects who participated in the study, with 4 subjects common to both conditions. Force, loading rates, jump height, and kinematics were analyzed during jumps with three distinct landings: two-footed toe-heel, one-footed toe-heel, and flat-footed. Gravity replacement loads of 45%, 60%, 75%, and 100% bodyweight were used in the ZGS; because of time constraints, these loads were limited to 60% and 75% bodyweight in parabolic flight. RESULTS: Average peak ground-reaction forces during landing ranged between 1902+/-607 and 2631+/-663 N in the ZGS and between 1683+/-807 and 2683+/-1174 N in the KC-135. No significant differences were found between the simulated and true microgravity conditions, but neither condition achieved the magnitudes found in 1 G. CONCLUSION: Data support the hypothesis that jumping exercises can impart high-impact forces during weightlessness and that the custom-designed ZGS will replicate what is experienced in true microgravity.


Assuntos
Perna (Membro)/fisiologia , Movimento/fisiologia , Ausência de Peso , Adulto , Feminino , Humanos , Joelho/fisiologia , Masculino , Músculo Esquelético/fisiologia , Suporte de Carga/fisiologia , Simulação de Ausência de Peso
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA